CellaVision-DM96
  
  
CellaVision® DM96 Automated Digital Morphology System  
Know Your Image
 
The CellaVision DM96 allows more laboratories to analyze both blood and body fluid smears in a safe and comfortable way.

Brochure_DM96.pdfClick here to download the brochure.

Reduce Review Time for Differentials

  • Plan for increasing workload without increasing labor
  • Reduce the time to review each smear
  • Utilize experienced technologists' skills and time more effectively

Standardize Your Lab’s Differential Results 

  • Reduce subjectivity of cell identification with automatic cell location and pre-classification
  • Standardize quality of results
  • Promote confidence within your lab by using the optional competency software

Enhance Technologists' Morphology Skills  

  • Simplify training with on-board reference cell image library
  • Allow hospital services to access, review and report results from any location using stored images
  • Collaborate in real-time with clinicians

Improve Employee Satisfaction

  • Performing differentials with the DM96 does not fatigue eyes, necks or wrists like microscopy can
  • Simplify scheduling and staffing
Automating Smear Analysis Safely, Comfortably, and Efficiently
 
Slide Methods for Peripheral Blood Automated slide maker and stainers, Hemaprep®-Mini Prep® automated smears, Manual Smears
Slide Methods for Body Fluids Cyto Centrifuged preparations (Settings for Shandon™, Wescor™, Statspin™)
Stains Romanowsky stains (Wright, May Grünwald, Giemsa)
On Board Capacity Up to 96 slides in magazines of 12 slides each      
Orange Magazines (Peripheral Blood);  Blue Magazines (Body Fluid)
Throughput for Peripheral Blood Up to 35 slides/hr (100 WBC + RBC + PLT)
Up to 60 slides/hr (RBC + PLT)
Throughput for Body Fluids    Up to 25 slides/hr (100 WBC @ 10x)
Up to 7 slides/hr (100 WBC @ 10X +50x)
Throughput for Digital Slides Up to 30 slides/hr (10mm x 10mm @ 10x)
Up to 2 slides/hr (10mm x 10mm @ 10x + 50x)
Slide Image Memory Requirements for Peripheral Blood Approximately 6MB  (100 WBC + RBC + PLT)   
Slide Image Memory Requirements for Body Fluids Approximately 5MB  (100 WBC)     
Approximately 10MB (100 WBC @ 10x)    
Approximately 150MB (100WBC @ 10x + 50x)
Slide Image Memory Requirements for Digital Slides Approximately 45MB (10mm x 10mm @ 10x) 
Approximately 500MB (10mm x 10mm @ 10x + 50x)
 
For additional specifications, please refer to the brochure.
Automatic cell location and pre-classification improves resource utilization, the quality of results and employee satisfaction.  An example of a labor benefit is highly skilled medical technologists are able to devote more time to difficult cases that require careful analysis and assessment.  The ability to archive enables hospitals to look at previous cell images for long term case management.
Efficiency
Automatic cell location and pre-classification, along with unique cell views, reduce the time spent performing differentials, training new technologists and monitoring proficiency.
Proficiency
The DM96 allows different technologists to perform differentials at the same high level of consistency.  The system provides traceability of results at the individual cell level.
Connectivity   
Multiple remote review stations provide supervisory review, inter-/intra-lab comparison and the opportunity for real time collaboration with pathology DM analyzers to share a working database with other DM analyzers on the same network.
Collaboration
As a result of network integration, the DM96 will save clinicians time with remote real-time access to a patient’s image history.
 © Copyright 2012 Sysmex